Login
HOME     PROFILE    SOLUTIONS    APPLICATIONS    GREEN BUILDING    RESOURCES    CONTACT US    SITEMAP    FEEDBACK    NEWS  
SunCarrier Omega


SunCarrier - Technical Details


SunCarrier 70 | 120 | 160 | 220 | 260 | 300


Special Construction

Special Construction

SunCarrier model SunCarrier 70 SunCarrier 120 SunCarrier 160
Rotational axis

azimuth (solar angle of arrival), single-axis tracking system, tracking through vertical axis

Rotational angle

max.2200

max.2200

max.2200

Module

all common types and sizes of modules may be used

Recorded power output*

up to 14,000 Wp* up to 24,000 Wp* up to 40,000 Wp*
Pitch angle of module surface 300 to the horizontal 300 to the horizontal 400 to the horizontal
Panel area
[width x height]
max. 84.05 m
(12.415 m x 6.77 m)
119.58 m
(16.16 m 7.40 m)
163.20 m
(1.60 m 17.00 m = 27.20 m)
Height above clearance surface approx. 4 m approx. 4.30 m approx. 4 m
Foundation

Concrete foundation (6 m x 6 m) or screw-in foundation

Screw-in foundation or concrete foundation (diameter: 6.20 m)

Screw-in foundation or concrete foundation (diameter: 12.00 m)

Control system

Memory Programmable Controller = MPC (for time, date and location coordinates with astronomic calculation algorithms)

back tracking to reduce shade

 
Drive**

multi-stage gear, formlocked link between chain wheel and anchor cable

Electric motor with break function and a three stage planetary gear

Dead weight
[steel structure, galvanised, without module]
2,300 kg 4,500 kg 8,000 kg
Building approval

structural design check by experts by Bavarian State Testing Authority (LGA)

compliant with Eurocode 1,subject to technical modifications

structural design check by experts with a calculated safety factor of at least 1.6 tested by the Bavarian State Testing Authority (LGA), CE certified

Wind load*** Gale speed pressure of 1.00 kN/m(144 km/h), compliant with Eurocode 1 DIN EN 1991-4:2005 compliant with UNI EN1991-1-1:2005-07,wind zone 4, area category II, 121.3 km/h gale speed or gale speed pressure of 0.71 kN/m compliant with I.F.I. Wind certificate and UNI EN1991-1-4: 2005, wind zone 4, area category II, 120.5 km/h gale speed or gale speed pressure of 0.70 kN/m
Area of use open spaces from 25 to 55 degrees of latitude, northern or southern hemisphere


High-performance park systems

SunCarrier model SunCarrier 220 SunCarrier 260 SunCarrier 300
Rotational axis

azimuth (solar angle of arrival), single-axis tracking system, tracking through vertical axis

Rotational angle

max.2200

max.2200

max.2200

Module

all common types and sizes of modules may be used

Recorded power output*

up to 40,000 Wp* up to 48,000 Wp* up to 53,000 Wp*
Pitch angle of module surface

30 to the horizontal

Panel area
[width x height]
212.10 m
(21.00 m 10.10 m)
247.52 m
(22.10 m 11.20 m),module surface area can be extended up to 5 %
287,50 m
(23.00 m 12.50 m)
Height above clearance surface approx. 6 m approx. 6.50 m approx. 7.20 m
Foundation

Concrete foundation (diameter: 12.00 m)

Control system

Memory Programmable Controller = MPC (for time, date and location coordinates with astronomic calculation algorithms)

Drive**

Electric motor with break function and a three stage planetary gear Dead weight

Dead weight
[steel structure, galvanised, without module]
10,000 kg 11,300 kg 12,900 kg
Building approval

structural design check by experts with a calculated safety factor of at least 1.6 tested by the Bavarian State Testing Authority (LGA), CE certified

Wind load*** 101.9 km/h, compliant with DIN 1055,Part 4 - 1986 128.9 km/h, compliant with DIN 1055,Part 4 - 2005 128.9 km/h, compliant with DIN 1055,Part 4 - 2005
Area of use open spaces from 25 to 55 degrees of latitude, northern or southern hemisphere


* Recorded power output: Watt peak = standard by which the power of solar cells and solar modules is measured), depending on the module type

** Drive: SunCarrier 120 | 160 | 220 | 260: brake motor 0.37 kW, Gearing i=1:1,595, Capacity approx. 0.4 kWh/day,SunCarrier 300: brake motor 0.75 kW, Gearing i=1:1,639, Capacity approx. 0.6 kWh/day, interlocking connection between chain wheel and anchor chain

*** Wind load: determination of characteristic loads by the Institut fr Industrie-Aerodynamik GmbH (IFI) (Institute for Industrial Aerodynamics) at the Aachen Technical College

Suncarrier-Omega-verticle-line

Testimonials


DSG Deutsche Solargesellschaft

Trustworthiness and reliability have been the basis of our cooperation with a+f mbH. Our solar park, consisting of 60 SunCarrier units, is the very first solar park installation realized with SunCarrier tracking systems in Spain. The systems deliver constantly high performance throughout their lifetime of operation. We are happily convinced of the uniqueness and effectiveness of the SunCarrier systems. We are proud of being part of the success story of these products.


Mr Joachim Kruck, Managing Director
DSG Deutsche Solargesellschaft
Read More

Visit SunCarrier Omega Photo Gallery
Watch SunCarrier Omega Video Gallery
Inter Solar Award Winner


Follow Us On Our BLOG
All rights reserved to SunCarrier Omega Pvt. Ltd.
Designed, Developed and Maintained by RSolutions.
Best viewed in 1024 x 768 (IE6+).